Back to Search Start Over

Quantitative Measurement on Contrast-Enhanced CT Distinguishes Small Clear Cell Renal Cell Carcinoma From Benign Renal Tumors: A Multicenter Study.

Authors :
Luo, Shiwei
Lin, Wanxian
Wu, Jialiang
Zhang, Wanli
Kui, Xiaoyan
Lai, Shengsheng
Wei, Ruili
Pang, Xinrui
Wang, Ye
He, Chutong
Liu, Jun
Yang, Ruimeng
Source :
Academic Radiology; Apr2024, Vol. 31 Issue 4, p1460-1471, 12p
Publication Year :
2024

Abstract

To evaluate the potential of quantitative measurements on contrast-enhanced CT (CECT) in differentiating small (≤4 cm) clear cell renal cell carcinoma (ccRCC) from benign renal tumors, including fat-poor angiomyolipoma (fpAML) and renal oncocytoma (RO). 244 patients with pathologically confirmed ccRCC (n = 184) and benign renal tumors (fpAML, n = 50; RO, n = 10) were randomly assigned into training cohort (n = 193) and test cohort 1 (n = 51), while external test cohort 2 (n = 50) was from another hospital. Quantitative parameters were obtained from CECT (unenhanced phase, UP; corticomedullary phase, CMP; nephrographic phase, NP; excretory phase, EP) by measuring attenuation of renal mass and cortex and subsequently calculated. Univariable and multivariable logistic regression analyses were performed to evaluate the association between these parameters and ccRCC. Finally, the constructed models were compared with radiologists' diagnoses. In univariable analysis, UP-related parameters, particularly UP C-T (cortex minus tumor attenuation on UP), demonstrated AUC of 0.766 in training cohort, 0.901 in test cohort 1, 0.805 in test cohort 2. The heterogeneity-related parameter SD (standard deviation) showed AUC of 0.781, 0.834, and 0.875 respectively. In multivariable analysis, model 1 incorporating UP C-T , NP C-T (cortex minus tumor attenuation on NP), CMP T -UP T (tumor attenuation on CMP minus UP), and SD yielded AUC of 0.866, 0.923, and 0.949 respectively. When compared with radiologists, multivariate models demonstrated higher accuracy (0.800–0.860) and sensitivity (0.794–0.971) than radiologists' assessments (accuracy: 0.700–0.720, sensitivity: 0.588–0.706). Quantitative measurements on CECT, particularly UP- and heterogeneity-related parameters, have potential to discriminate ccRCC and benign renal tumors (fpAML, RO). [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
10766332
Volume :
31
Issue :
4
Database :
Supplemental Index
Journal :
Academic Radiology
Publication Type :
Academic Journal
Accession number :
176547503
Full Text :
https://doi.org/10.1016/j.acra.2023.10.014