Back to Search Start Over

High-frequency low-tidal volume ventilation improves procedural and long-term clinical outcomes in persistent atrial fibrillation ablation: Prospective multicenter registry.

Authors :
Osorio, Jose
Hincapie, Daniela
Varley, Allyson L.
Silverstein, Joshua R.
Matos, Carlos D.
Thosani, Amit J.
Thorne, Christopher
D'Souza, Benjamin
Alviz, Isabella
Gabr, Mohamed
Rajendra, Anil
Oza, Saumil
Sharma, Dinesh
Hoyos, Carolina
Singleton, Matthew J.
Mareddy, Chinmaya
Velasco, Alejandro
Zei, Paul C.
Sauer, William H.
Romero, Jorge E.
Source :
Heart Rhythm; Feb2025, Vol. 22 Issue 2, p432-442, 11p
Publication Year :
2025

Abstract

High-frequency, low-tidal volume (HFLTV) ventilation increases the efficacy and efficiency of radiofrequency catheter ablation (RFCA) of paroxysmal atrial fibrillation. Whether those benefits can be extrapolated to RFCA of persistent atrial fibrillation (PeAF) is undetermined. The purpose of this study was to evaluate whether using HFLTV ventilation during RFCA in patients with PeAF is associated with improved procedural and long-term clinical outcomes compared to standard ventilation (SV). In this prospective multicenter registry (REAL-AF), patients who had undergone pulmonary vein isolation (PVI) + posterior wall isolation (PWI) for PeAF using either HFLTV ventilation or SV were included. The primary efficacy outcome was freedom from all-atrial arrhythmias at 12 months. Secondary outcomes included procedural and long-term clinical outcomes and complications. A total of 210 patients were included (HFLTV=95 vs. SV=115) in the analysis. There were no differences in baseline characteristics between the groups. Procedural time (80 [66–103.5] minutes vs 110 [85–141] minutes; P <.001), total radiofrequency (RF) time (18.73 [13.93–26.53] minutes vs 26.15 [20.30–35.25] minutes; P <.001), and pulmonary vein RF time (11.35 [8.78–16.69] minutes vs 18 [13.74–24.14] minutes; P <.001) were significantly shorter using HFLTV ventilation compared with SV. Freedom from all-atrial arrhythmias was significantly higher with HFLTV ventilation compared with SV (82.1% vs 68.7%; hazard ratio 0.41; 95% confidence interval [0.21–0.82]; P =.012), indicating a 43% relative risk reduction and a 13.4% absolute risk reduction in all-atrial arrhythmia recurrence. There was no difference in long-term procedure-related complications between the groups (HFLTV 1.1% vs SV 0%, P =.270). In patients undergoing RFCA with PVI + PWI for PeAF, the use of HFLTV ventilation was associated with higher freedom from all-atrial arrhythmias at 12-month follow-up, with significantly shorter procedural and RF times compared to SV, while reporting a similar safety profile. [Display omitted] [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
15475271
Volume :
22
Issue :
2
Database :
Supplemental Index
Journal :
Heart Rhythm
Publication Type :
Academic Journal
Accession number :
182158062
Full Text :
https://doi.org/10.1016/j.hrthm.2024.07.094