Back to Search Start Over

Limiting Current Operation of Proton Exchange Membrane Fuel Cells.

Authors :
St-Pierre, J.
Wetton, B.
Kim, G.-S.
Promislow, K.
Source :
Journal of The Electrochemical Society; Feb2007, Vol. 154 Issue 2, pB186-B193, 8p
Publication Year :
2007

Abstract

Operation of proton exchange membrane fuel cells at high current densities is a potential option to reduce fuel cell cost and volume for automotive applications. This operating regime was investigated using low cell voltages leading to limiting current density values. A zero-dimensional cell voltage model and a one-dimensional low cell voltage model were developed and validated. The operating conditions required for model applicability were summarized. The gas diffusion electrode overall mass transfer coefficient was identified as a key design parameter. [ABSTRACT FROM AUTHOR]