Back to Search Start Over

Comparison of 4.5- and 5.5-mm Cannulated Stainless Steel Screws for Fifth Metatarsal Jones Fracture Fixation.

Authors :
Porter, David A.
Dobslaw, Rebecca
Duncan, Melissa
Source :
Foot & Ankle International; Jan2009, Vol. 30 Issue 1, p27-33, 7p
Publication Year :
2009

Abstract

The article presents a study which compared the effectiveness of 5.5-millimeter (mm) cannulated screw fixation for fifth metatarsal stress fractures in athletes with a 4.5-mm screw. It describes the different types of fifth metatarsal base fractures. Fractures in the twenty athletes treated surgically with 5.5-mm cannulated screw were evaluated for clinical and radiographic healing. Details of the study findings are explained.