Back to Search Start Over

Efficacy of an Artificial Neural Network–Based Approach to Endoscopic Ultrasound Elastography in Diagnosis of Focal Pancreatic Masses.

Authors :
Săftoiu, Adrian
Vilmann, Peter
Gorunescu, Florin
Janssen, Jan
Hocke, Michael
Larsen, Michael
Iglesias–Garcia, Julio
Arcidiacono, Paolo
Will, Uwe
Giovannini, Marc
Dietrich, Cristoph F.
Havre, Roald
Gheorghe, Cristian
McKay, Colin
Gheonea, Dan Ionuţ
Ciurea, Tudorel
Source :
Clinical Gastroenterology & Hepatology; Jan2012, Vol. 10 Issue 1, p84-90.e1, 0p
Publication Year :
2012

Abstract

Background & Aims: By using strain assessment, real-time endoscopic ultrasound (EUS) elastography provides additional information about a lesion''s characteristics in the pancreas. We assessed the accuracy of real-time EUS elastography in focal pancreatic lesions using computer-aided diagnosis by artificial neural network analysis. Methods: We performed a prospective, blinded, multicentric study at of 258 patients (774 recordings from EUS elastography) who were diagnosed with chronic pancreatitis (n = 47) or pancreatic adenocarcinoma (n = 211) from 13 tertiary academic medical centers in Europe (the European EUS Elastography Multicentric Study Group). We used postprocessing software analysis to compute individual frames of elastography movies recorded by retrieving hue histogram data from a dynamic sequence of EUS elastography into a numeric matrix. The data then were analyzed in an extended neural network analysis, to automatically differentiate benign from malignant patterns. Results: The neural computing approach had 91.14% training accuracy (95% confidence interval [CI], 89.87%–92.42%) and 84.27% testing accuracy (95% CI, 83.09%–85.44%). These results were obtained using the 10-fold cross-validation technique. The statistical analysis of the classification process showed a sensitivity of 87.59%, a specificity of 82.94%, a positive predictive value of 96.25%, and a negative predictive value of 57.22%. Moreover, the corresponding area under the receiver operating characteristic curve was 0.94 (95% CI, 0.91%–0.97%), which was significantly higher than the values obtained by simple mean hue histogram analysis, for which the area under the receiver operating characteristic was 0.85. Conclusions: Use of the artificial intelligence methodology via artificial neural networks supports the medical decision process, providing fast and accurate diagnoses. [Copyright &y& Elsevier]

Details

Language :
English
ISSN :
15423565
Volume :
10
Issue :
1
Database :
Supplemental Index
Journal :
Clinical Gastroenterology & Hepatology
Publication Type :
Academic Journal
Accession number :
69848350
Full Text :