Back to Search Start Over

A Rotor Condition Monitor for Squirrel-Cage Induction Machines

Authors :
Siyambalapitiya, D. J. Tilak
McLaren, Peter G.
Acarnley, Paul P.
Source :
IEEE Transactions on Industry Applications; January 1978, Vol. 13 Issue: 2 p334-340, 7p
Publication Year :
1978

Abstract

Rotor temperature is of concern in both short-term machine protection and in longer term condition monitoring systems for large induction machines. Unduly large temperatures can arise under severe operating conditions such as stall and overload. A cage rotor condition monitoring system using direct temperature measurement is described. Under running conditions, it continuously transmits temperature information about strategic points on the rotor via an optical link. Possible rotor circuit imperfections are broken bars and end rings, single or multiple, and the deterioration of bar/end ring joints. The possibility of using temperature information for the identification of these faults is also investigated.

Details

Language :
English
ISSN :
00939994
Volume :
13
Issue :
2
Database :
Supplemental Index
Journal :
IEEE Transactions on Industry Applications
Publication Type :
Periodical
Accession number :
ejs14203388
Full Text :
https://doi.org/10.1109/TIA.1987.4504910