Start Over
Determination of Trace Levels of Aluminum by Capillary Electrophoresis with Lumogallion Fluorometric Detection
- Source :
- Journal of Chromatographic Science; July 1997, Vol. 35 Issue: 7 p333-333, 1p
- Publication Year :
- 1997
-
Abstract
- The determination of aluminum in water samples is performed with capillary electrophoresis after a convenient preconcentration procedure involving simple evaporation and subsequent filtration. By using a fluorescence detector, a detection limit lower than 20 µ/L aluminum is readily obtained. Only one peak from the aluminum—lumogallion complex is observed, which indicates the elimination of interference from foreign ions and lumogallion.
Details
- Language :
- English
- ISSN :
- 00219665 and 1945239X
- Volume :
- 35
- Issue :
- 7
- Database :
- Supplemental Index
- Journal :
- Journal of Chromatographic Science
- Publication Type :
- Periodical
- Accession number :
- ejs27380611
- Full Text :
- https://doi.org/10.1093/chromsci/35.7.333