Back to Search Start Over

AEROSOL AND SPLATTER CONTAMINATION FROM THE OPERATIVE SITE DURING ULTRASONIC SCALING

Authors :
HARREL, STEVE K.
BARNES, JAMES B.
RIVERA-HIDALGO, FRANCISCO
Source :
Journal of the American Dental Association; September 1998, Vol. 129 Issue: 9 p1241-1249, 9p
Publication Year :
1998

Abstract

As concern about indoor air quality increases, attention is being placed on the aerosol and splatter produced during dental procedures. This study quantifies the contamination produced by ultrasonic scalers during in vitro scaling without coolant water. When compared with the handheld curette used as a control, all ultrasonic scalers and tips tested produced significant aerosol and splatter regardless of the type of scaler, the power level or the insert. The ADA-recommended method for controlling contaminated aerosol and splatter is the use of a large-bore high-volume evacuator. This study supports the ADA recommendation of use of a high-volume evacuator whenever ultrasonic scaling is performed.

Details

Language :
English
ISSN :
00028177
Volume :
129
Issue :
9
Database :
Supplemental Index
Journal :
Journal of the American Dental Association
Publication Type :
Periodical
Accession number :
ejs34574806
Full Text :
https://doi.org/10.14219/jada.archive.1998.0421