Back to Search
Start Over
Poster session 3
- Source :
- European Journal of Echocardiography; December 2015, Vol. 16 Issue: Supplement 2 pS102-S102, 1p
- Publication Year :
- 2015
-
Abstract
- Purpose: We developed a transthoracic echo simulator that can measure psychomotor skill in echo to assist in training as well as for certification of competence. The simulator displays cine loops on a computer in response to the user scanning a mannequin with a mock transducer. The skill metric is the deviation angle between the image acquired by the user and the anatomically correct plane for the specified view. We sought to determine whether the simulator-based test could distinguish levels of expertise. Methods: Attendees at an echo course or at the annual meeting of the Swedish Heart Association were invited to take a 15 min test on the simulator. On the test, the user scanned the mannequin and acquired 4 views: parasternal long axis (pLAX) in patient 1, apical 4 chamber (a4c) and aLAX in patient 2, and pLAX in patient 3. Scan time was limited to 15 min. Attendees were asked regarding current work status, position, and experience with echo assessed from duration in years and procedure volume in the past 12 months. Results: Of the 61 participants there were 22 sonographers, 2 nurses, and 37 doctors who were all in practice except 1 doctor who was a resident. The data of nurses was combined with that of sonographers because their procedure volume was nearer to that of sonographers (850 ± 599 tests/yr) than doctors (312 ± 393, p < 0.001). Doctors and non-doctors had similar duration of experience (9 ± 8 vs. 12 ± 11 yrs, p=NS). The test was not completed by 12 participants (18%) but unfamiliarity with the simulator may have contributed because the deviation angle for pLAX dropped between the first and third patients (23 ± 11 to 18 ± 10 degrees, p<0.020). The average deviation angle over the 4 views was slightly lower for sonographers than for doctors (26 ± 11 vs. 30 ± 14 degrees, p=NS). The deviation angle for pLAX (55 ± 37 degrees) was higher than for a4C (17 ± 22 degrees) or either pLAX view (p<0.00001). pLAX was the only view whose deviation angle correlated significantly with experience and only with procedure volume (r=-0.302, p=0.025). Conclusions: The results of this study demonstrate that the skill metric employed, angle of deviation between the plane of an acquired view and the plane of the anatomically correct image for that view, can distinguish the relative experience of sonographers and doctors in practice. Simulation-based testing provides objective and quantitative assessment of the psychomotor skill of image acquisition and may be of value in certification of trainees and in maintenance of certification examination of practicing sonographers and doctors.
Details
- Language :
- English
- ISSN :
- 15252167 and 15322114
- Volume :
- 16
- Issue :
- Supplement 2
- Database :
- Supplemental Index
- Journal :
- European Journal of Echocardiography
- Publication Type :
- Periodical
- Accession number :
- ejs38336275
- Full Text :
- https://doi.org/10.1093/ehjci/jev277