Back to Search Start Over

Superselective intra-arterial hepatic injection of indocyanine green (ICG) for fluorescence image-guided segmental positive staining: experimental proof of the concept

Authors :
Diana, Michele
Liu, Yu-Yin
Pop, Raoul
Kong, Seong-Ho
Legnèr, Andras
Beaujeux, Remy
Pessaux, Patrick
Soler, Luc
Mutter, Didier
Dallemagne, Bernard
Marescaux, Jacques
Source :
Surgical Endoscopy; March 2017, Vol. 31 Issue: 3 p1451-1460, 10p
Publication Year :
2017

Abstract

Intraoperative liver segmentation can be obtained by means of percutaneous intra-portal injection of a fluorophore and illumination with a near-infrared light source. However, the percutaneous approach is challenging in the minimally invasive setting. We aimed to evaluate the feasibility of fluorescence liver segmentation by superselective intra-hepatic arterial injection of indocyanine green (ICG). Eight pigs (mean weight: 26.01 ± 5.21 kg) were involved. Procedures were performed in a hybrid experimental operative suite equipped with the Artis Zeego®, multiaxis robotic angiography system. A pneumoperitoneum was established and four laparoscopic ports were introduced. The celiac trunk was catheterized, and a microcatheter was advanced into different segmental hepatic artery branches. A near-infrared laparoscope (D-Light P, Karl Storz) was used to detect the fluorescent signal. To assess the correspondence between arterial-based fluorescence demarcation and liver volume, metallic markers were placed along the fluorescent border, followed by a 3D CT-scanning, after injecting intra-arterial radiological contrast (n= 3). To assess the correspondence between arterial and portal supplies, percutaneous intra-portal angiography and intra-arterial angiography were performed simultaneously (n= 1). Bright fluorescence signal enhancing the demarcation of target segments was obtained from 0.1 mg/mL, in matter of seconds. Correspondence between the volume of hepatic segments and arterial territories was confirmed by CT angiography. Higher background fluorescence noise was found after positive staining by intra-portal ICG injection, due to parenchymal accumulation and porto-systemic shunting. Intra-hepatic arterial ICG injection, rapidly highlights hepatic target segment borders, with a better signal-to-background ratio as compared to portal vein injection, in the experimental setting.

Details

Language :
English
ISSN :
09302794 and 14322218
Volume :
31
Issue :
3
Database :
Supplemental Index
Journal :
Surgical Endoscopy
Publication Type :
Periodical
Accession number :
ejs39768722
Full Text :
https://doi.org/10.1007/s00464-016-5136-y