Back to Search Start Over

Development and Validation of a Simple High-Performance Liquid Chromatography Method for Estimation of Felodipine in Rabbit Plasma: Application to Pharmacokinetic Study

Authors :
Monohar Pandey, Murali
Y. Charde, Shrikant
Jaipal, A.
P. Raut, Prashant
Goel, Puneet
Kumar, Love
Source :
Current Pharmaceutical Analysis; July 2017, Vol. 13 Issue: 4 p321-327, 7p
Publication Year :
2017

Abstract

Background: A new, simple, specific and sensitive reverse-phase liquid chromatographic method was developed and validated for the estimation of felodipine (FDP) in rabbit plasma using fluorescence detector. Materials and Methods: Plasma standard were prepared using a simple and one-step protein precipitation method and 50 μ l of the standard solutions were injected into the column. The method was found to be linear in the concentration range of 10–1000 ng/ml. The developed bioanalytical method was validated as per standard guidelines. Validation study results demonstrated accuracy, precision, sensitivity and selectivity of the proposed method. Results: The developed method was successfully employed in the determination of FDP in plasma samples obtained from the pharmacokinetic study of the immediate release tablets in rabbits.

Details

Language :
English
ISSN :
15734129
Volume :
13
Issue :
4
Database :
Supplemental Index
Journal :
Current Pharmaceutical Analysis
Publication Type :
Periodical
Accession number :
ejs43041863
Full Text :
https://doi.org/10.2174/1573412912666160824120801