Failure of Connecting Clamps in Electrical Terminal Blocks
- Source :
- Praktische Metallographie.Practical Metallography; June 2023, Vol. 60 Issue: 6 p382-401, 20p
- Publication Year :
- 2023
-
Abstract
- The failure of fastening elements in electrical terminal blocks was attributed to various material-related causes. While the casehardened terminal screws broke due to hydrogen embrittlement, the material-related cause of the plastic deformations of the roof-shaped washers and the stripping of the threads of the square nuts are undersizing and an insufficient strength for this particular application.