Back to Search Start Over

Production of Auger-electron-emitting 103mRh via a 103Pd/103mRh generator using an anion-exchange resin

Authors :
Ohya, Tomoyuki
Ichinose, Jun
Nagatsu, Kotaro
Sugo, Yumi
Ishioka, Noriko
Watabe, Hiroshi
Itoh, Masatoshi
Minegishi, Katsuyuki
Zhang, Ming-Rong
Source :
Radiochimica Acta; January 2024, Vol. 112 Issue: 1 p37-43, 7p
Publication Year :
2024

Abstract

Rhodium-103m is one of the most attractive Auger electron emitters for internal radiotherapy. The half-life of 103mRh is relatively short (56.114 min). Therefore, it needs to be produced using a generator for clinical use. Most studies of 103Pd/103mRh generators using anion-exchange resins were carried out over 50 years ago. However, these resins are no longer commercially available. In the present study, we tested a 103Pd/103mRh generator using alternative anion-exchange resins (i.e., IRA904, IRA410, SA20A, and SA11AL). No-carrier-added 103Pd was used to make the generators. The 103mRh product was eluted from the generators using 6 mL of 0.1 M HCl with a flow rate 0.5 mL/min. The generator made from SA11AL showed good performance, with a yield of 39 %, an impurity level of 103Pd in the product of 0.29 %, and an operation time of 14 min. This makes this generator competitive with previously developed ones.

Details

Language :
English
ISSN :
00338230
Volume :
112
Issue :
1
Database :
Supplemental Index
Journal :
Radiochimica Acta
Publication Type :
Periodical
Accession number :
ejs65131655
Full Text :
https://doi.org/10.1515/ract-2023-0238