Back to Search
Start Over
Complete event-by-event $\alpha/\gamma(\beta)$ separation in a full-size ${\mathrm{TeO}}_{2}$ CUORE bolometer by Neganov-Luke-magnified light detection
- Source :
- Phys.Rev.C, Phys.Rev.C, 2018, 97 (3), pp.032501. ⟨10.1103/PhysRevC.97.032501⟩, Physical Review C, Physical Review C, 2018, 97 (3), pp.032501. ⟨10.1103/PhysRevC.97.032501⟩, Phys.Rev.C, 2018, 97 (3), pp.032501. 〈10.1103/PhysRevC.97.032501〉
- Publication Year :
- 2018
- Publisher :
- HAL CCSD, 2018.
-
Abstract
- In the present work, we describe the results obtained with a large ($\approx 133$ cm$^3$) TeO$_2$ bolometer, with a view to a search for neutrinoless double-beta decay ($0\nu\beta\beta$) of $^{130}$Te. We demonstrate an efficient $\alpha$ particle discrimination (99.9\%) with a high acceptance of the $0\nu\beta\beta$ signal (about 96\%), expected at $\approx 2.5$ MeV. This unprecedented result was possible thanks to the superior performance (10 eV rms baseline noise) of a Neganov-Luke-assisted germanium bolometer used to detect a tiny (70 eV) light signal from the TeO$_2$ detector, dominated by $\gamma$($\beta$)-induced Cherenkov radiation but exhibiting also a clear scintillation component. The obtained results represent a major breakthrough towards the TeO$_2$-based version of CUORE Upgrade with Particle IDentification (CUPID), a ton-scale cryogenic $0\nu\beta\beta$ experiment proposed as a follow-up to the CUORE project with particle identification. The CUORE experiment began recently a search for neutrinoless double-beta decay of $^{130}$Te with an array of 988 125-cm$^3$ TeO$_2$ bolometers. The lack of $\alpha$ discrimination in CUORE makes $\alpha$ decays at the detector surface the dominant background component, at the level of $\approx 0.01$ counts/(keV kg y) in the region of interest. We show here, for the first time with a CUORE-size bolometer and using the same technology as CUORE for the readout of both heat and light signals, that surface $\alpha$ background can be fully rejected.<br />Comment: The second version reflects the changes made after PRC referees' comments
- Subjects :
- CUORE
Physics - Instrumentation and Detectors
electron: particle identification
radiation: Cherenkov
tellurium: oxygen
helium: particle identification
photon: particle identification
High Energy Physics - Experiment
helium: background
bolometer
double-beta decay: (0neutrino)
[ PHYS.HEXP ] Physics [physics]/High Energy Physics - Experiment [hep-ex]
[PHYS.HEXP]Physics [physics]/High Energy Physics - Experiment [hep-ex]
tellurium: nuclide
[PHYS.PHYS.PHYS-INS-DET]Physics [physics]/Physics [physics]/Instrumentation and Detectors [physics.ins-det]
[ PHYS.PHYS.PHYS-INS-DET ] Physics [physics]/Physics [physics]/Instrumentation and Detectors [physics.ins-det]
performance
background: suppression
Subjects
Details
- Language :
- English
- ISSN :
- 24699985 and 24699993
- Database :
- OpenAIRE
- Journal :
- Phys.Rev.C, Phys.Rev.C, 2018, 97 (3), pp.032501. ⟨10.1103/PhysRevC.97.032501⟩, Physical Review C, Physical Review C, 2018, 97 (3), pp.032501. ⟨10.1103/PhysRevC.97.032501⟩, Phys.Rev.C, 2018, 97 (3), pp.032501. 〈10.1103/PhysRevC.97.032501〉
- Accession number :
- edsair.arXiv.dedup...0ea2578a7c2b8ff2faea39466d29f25d