Back to Search Start Over

Calibration of frequency domain reflectometry sensors to estimate soil moisture in a Geric Xanthic Ferralsol

Authors :
Abanto-Rodríguez, Carlos
Araújo, Wellington Farias
Chagas, Pollyana Cardoso
Chagas, Edvan Alves
João Lopes Monteiro, N.
Siqueira, Raphael Da Silva
Barbosa, Samara Martins [UNESP]
Melo, Valdinar Ferreira
Valero, Miguel A. Maffei
Univ Fed Roraima UFRR
Empresa Brasileira de Pesquisa Agropecuária (EMBRAPA)
Inst Fed Roraima IFRR
Universidade Estadual Paulista (Unesp)
Universidade Federal de Roraima-UFRR
Instituto Federal de Roraima-IFRR
Source :
Web of Science, Repositório Institucional da UNESP, Universidade Estadual Paulista (UNESP), instacron:UNESP, Scopus
Publication Year :
2020
Publisher :
Univ Centroccidential Lisandro Alvarado, 2020.

Abstract

Made available in DSpace on 2021-06-25T10:14:12Z (GMT). No. of bitstreams: 0 Previous issue date: 2020-01-01 Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq) The use of irrigation is essential to increase crop productivity; however, for efficient water management, it is necessary to more accurately estimate soil moisture. For this reason, the objective in this work was to calibrate FDR model 10HS frequency domain reflectometry sensors (Decagon Devices) for use in a Geric Xanthic Ferralsol type soil. For the calibration, non disturbed soil samples were collected in PVC pipes at two depths (0-20 and 20-40 cm), with four repetitions each and they were placed in trays with distilled water until saturation. Subsequently the sensors were introduced in the sample to obtain the moisture at the saturation point. Then, the samples were placed in an oven at 60 ºC, until they reached approximately 10 % humidity. The results showed that the gross volumetric moisture data recorded before calibration did not coincide with the 1:1 line, presenting divergent behavior, thus demonstrating the need for calibration. According to the results, it is concluded that the equations generated with the data before the calibration overestimated the volumetric soil moisture, and the equations obtained after the calibration satisfactorily measure the moisture of the Geric Xanthic Ferralsol type soil. Programa de Pós-graduação em Biodiversidade e Biotecnologia da Rede BIONORTE Universidade Federal de Roraima-UFRR Universidade Federal de Roraima-UFRR Empresa Brasileira de Pesquisa Agropecuaria-EMBRAPA Roraima Programa de Pós-Graduação em Agronomia (POSAGRO) Universidade Federal de Roraima-UFRR Instituto Federal de Roraima-IFRR Universidade Estadual Paulista-UNESP Universidade Estadual Paulista-UNESP

Details

Language :
Spanish; Castilian
Database :
OpenAIRE
Journal :
Web of Science, Repositório Institucional da UNESP, Universidade Estadual Paulista (UNESP), instacron:UNESP, Scopus
Accession number :
edsair.dedup.wf.001..5823d06d3dbc3895f341ca1589b629db