Back to Search Start Over

Imagerie par résonance magnétique chez les patients porteurs de stimulateurs cardiaques et de défibrillateurs automatiques implantables : revue de la littérature. [Magnetic resonance imaging in patients with pacemakers and implantable cardioverter-defibrillators: a systematic review]

Authors :
Martins, Raphaël P
Baruteau, A.-E.
Treguer, F.
Césari, O.
Carsin-Nicol, Béatrice
Langella, B.
Leclercq, Christophe
Daubert, Jean-Claude
Mabo, Philippe
Laboratoire Traitement du Signal et de l'Image (LTSI)
Université de Rennes 1 (UR1)
Université de Rennes (UNIV-RENNES)-Université de Rennes (UNIV-RENNES)-Institut National de la Santé et de la Recherche Médicale (INSERM)
Service de cardiologie et maladies vasculaires [Rennes] = Cardiac, Thoracic, and Vascular Surgery [Rennes]
CHU Pontchaillou [Rennes]
CIC-IT Rennes
Hôpital Pontchaillou-Institut National de la Santé et de la Recherche Médicale (INSERM)
Service de cardiologie [Angers]
Centre Hospitalier Universitaire d'Angers (CHU Angers)
PRES Université Nantes Angers Le Mans (UNAM)-PRES Université Nantes Angers Le Mans (UNAM)
Service de radiologie et imagerie médicale [Rennes] = Radiology [Rennes]
Université de Rennes (UR)-Institut National de la Santé et de la Recherche Médicale (INSERM)
Source :
Annales de Cardiologie et d'Angéiologie, Annales de Cardiologie et d'Angéiologie, Elsevier Masson, 2010, 59 (4), pp.221-8. ⟨10.1016/j.ancard.2009.04.003⟩, Annales de Cardiologie et d'Angéiologie, 2010, 59 (4), pp.221-8. ⟨10.1016/j.ancard.2009.04.003⟩
Publication Year :
2010
Publisher :
HAL CCSD, 2010.

Abstract

International audience; The presence of a pacemaker or an implantable cardioverter-defibrillator was historically considered a contraindication to magnetic resonance imaging (MRI), due to the risks for both patient and device: reed-switch closure responsible for asynchronous pacing, inhibition of pacing, rapid ventricular pacing, heating on the lead tip or even device displacement... However, many recent studies demonstrate that if MRI is crucial for the management of the patient, it can be performed under specific monitoring and scanning conditions and after device reprogramming. The growing implication of device constructors in constructing a MRI safety device will perhaps extend in the future the indications of this imaging modality in implanted patients.

Details

Language :
French
ISSN :
00033928 and 17683181
Database :
OpenAIRE
Journal :
Annales de Cardiologie et d'Angéiologie, Annales de Cardiologie et d'Angéiologie, Elsevier Masson, 2010, 59 (4), pp.221-8. ⟨10.1016/j.ancard.2009.04.003⟩, Annales de Cardiologie et d'Angéiologie, 2010, 59 (4), pp.221-8. ⟨10.1016/j.ancard.2009.04.003⟩
Accession number :
edsair.dedup.wf.001..aba8621bd74f61c5d6d5d3a54066c5d8