Back to Search Start Over

Nearfield Acoustical Holography Research & Application On Compressor & Refrigerator

Authors :
Jianwen, Xu
Fagotti, Fabian
Jiang, Weikang
Source :
International Compressor Engineering Conference
Publication Year :
2012
Publisher :
Purdue University, 2012.

Abstract

In this paper, an algebraic formulation which expresses the dimensionless rate of entropy generation as a function of the heat exchanger geometry (number of transfer units), the thermal-hydraulic characteristics (friction factor and Colburn j-factor), and the operating conditions (heat transfer duty, core velocity, coil surface temperature, and fluid properties) is derived. It is shown that for heat exchanger with constant wall temperature (i.e., condensers and evaporators), there does exist a particular number of transfer units which minimizes the dimensionless rate of entropy generation. An algebraic expression for the optimum heat exchanger effectiveness, based on the working conditions, heat exchanger geometry and fluid properties, is also presented. The theoretical analysis led to the conclusion that a high effectiveness heat exchanger does not necessarily provide the best thermal-hydraulic design.

Details

Database :
OpenAIRE
Journal :
International Compressor Engineering Conference
Accession number :