Back to Search Start Over

Towards Measuring the Pu Self-Diffusion Coefficient in Polycrystalline U0.55Pu0.45O2±x

Authors :
Noyau, S.
Garcia, P.
Pasquet, B.
Roure, L.
Audubert, F.
Maitre, Alexandre
Axe 1 : procédés céramiques
Science des Procédés Céramiques et de Traitements de Surface (SPCTS)
Université de Limoges (UNILIM)-Ecole Nationale Supérieure de Céramique Industrielle (ENSCI)-Institut des Procédés Appliqués aux Matériaux (IPAM)
Université de Limoges (UNILIM)-Université de Limoges (UNILIM)-Institut de Chimie du CNRS (INC)-Centre National de la Recherche Scientifique (CNRS)-Université de Limoges (UNILIM)-Ecole Nationale Supérieure de Céramique Industrielle (ENSCI)-Institut des Procédés Appliqués aux Matériaux (IPAM)
Université de Limoges (UNILIM)-Université de Limoges (UNILIM)-Institut de Chimie du CNRS (INC)-Centre National de la Recherche Scientifique (CNRS)
Département d'Etudes des Combustibles (DEC)
CEA-Direction des Energies (ex-Direction de l'Energie Nucléaire) (CEA-DES (ex-DEN))
Commissariat à l'énergie atomique et aux énergies alternatives (CEA)-Commissariat à l'énergie atomique et aux énergies alternatives (CEA)
Source :
Defect and Diffusion Forum, Defect and Diffusion Forum, 2012, 323-325, pp.203-208. ⟨10.4028/www.scientific.net/DDF.323-325.203⟩, Defect and Diffusion Forum, Trans Tech Publications, 2012, 323-325, pp.203-208. ⟨10.4028/www.scientific.net/DDF.323-325.203⟩
Publication Year :
2012
Publisher :
HAL CCSD, 2012.

Abstract

International audience; This paper describes an original method to measure the plutonium self-diffusion coefficient in the mixed oxide U0.55Pu0.45O2±x. This method is based on using 242Pu as a tracer atom. A thin film of the tracer was deposited on the well-polished surface of the samples and then diffusion annealings were performed from 1500°C to 1700°C, in an Ar-H2 5% atmosphere. The oxygen potential was fixed at-395 kJ.mol-1. After annealing, the 242Pu self-diffusion profiles were established by means of secondary ion mass spectrometry (SIMS). The 242Pu concentration profiles were determined by assessing the relative U, Am and Pu ionisation yields according to the experimental parameters. The choice of favourable experimental conditions and the relevance of the resulting concentration profiles are discussed at length

Details

Language :
English
ISSN :
10120386
Database :
OpenAIRE
Journal :
Defect and Diffusion Forum, Defect and Diffusion Forum, 2012, 323-325, pp.203-208. ⟨10.4028/www.scientific.net/DDF.323-325.203⟩, Defect and Diffusion Forum, Trans Tech Publications, 2012, 323-325, pp.203-208. ⟨10.4028/www.scientific.net/DDF.323-325.203⟩
Accession number :
edsair.dedup.wf.001..d67b6fffaab5507ee13632ef5d79c073
Full Text :
https://doi.org/10.4028/www.scientific.net/DDF.323-325.203⟩