Back to Search Start Over

Influence of system design on heat distribution costs in district heating

Authors :
Thomas Nussbaumer
S. Thalmann
Source :
Energy. 101:496-505
Publication Year :
2016
Publisher :
Elsevier BV, 2016.

Abstract

The study introduces an economic analysis for district heating networks from 0.5 MW to 4 MW. The reference case describes a linear network with 1 MW input, 1 km pipeline length, and 2000 annual full-load hours corresponding to a linear heat density of 2 MWh input per year and meter of pipeline. Pipe diameter, connection load, fuel price, electricity price, and insulation class are investigated and the influence of linear and radial connection and the effect of the consumer distribution are evaluated. The reference case for an annuity of 5.1% p.a. and a heat price of 5.0 euro cent per kWh reveals heat distribution costs of 2.16 c/kWh for the optimum pipe diameter. For distributed heat consumers, the costs decrease to 1.99 c/kWh and for a radial network to 1.77 c/kWh. The evaluation reveals that district heating is related to diseconomies of scale for a linear network expansion at constant linear heat density and that the total costs are dominated by the capital costs. Consequently, the main requirement to minimise the heat distribution costs implies the use of the smallest technically feasible pipe diameter which refers to the maximum allowable differential pressure without inadmissible cavitation pitting.

Details

ISSN :
03605442
Volume :
101
Database :
OpenAIRE
Journal :
Energy
Accession number :
edsair.doi...........050f5bd98863492e6d40c1cddd1337e1
Full Text :
https://doi.org/10.1016/j.energy.2016.02.062