Back to Search Start Over

PULSE-ECHO PHASED ARRAY ULTRASONIC INSPECTION OF PULTRUDED ROD STITCHED EFFICIENT UNITIZED STRUCTURE (PRSEUS)

Authors :
P. H. Johnston
Donald O. Thompson
Dale E. Chimenti
Source :
AIP Conference Proceedings.
Publication Year :
2011
Publisher :
AIP, 2011.

Abstract

A PRSEUS test article was subjected to controlled impact on the skin face followed by static and cyclic axial compressions. Phased array ultrasonic inspection was conducted before impact, and after each of the test conditions. A linear phased array probe with a manual X‐Y scanner was used for interrogation. Ultrasound showed a delamination between the skin and stringer flange adjacent to the impact. As designed, the stitching in the flange arrested the lateral flaw formation. Subsequent ultrasonic data showed no delamination growth due to continued loading.