Back to Search Start Over

Cathodoluminescence measurements on green light-emitting GaP diodes

Authors :
H. Haefner
H. Morawetz
G. Oelgart
Source :
Physica Status Solidi (a). 63:495-500
Publication Year :
1981
Publisher :
Wiley, 1981.

Abstract

Green light-emitting GaP:N diodes (LED's) are investigated at room temperature using a scanning electron probe microanalyzer. Integral cathodoluminescence (CL) line scans across the p-n junction are carried out. The CL line scan is discussed in connection with the depth of the p-n junction and in comparison with the external quantum efficiency of the diodes. A higher concentration of non-radiative recombination centres are detected in some cases close to the p-n junction in the n-region. The injection ratio (under the forward-bias condition) is determined comparing CL with the electroluminescence. Mit einem Elektronenstrahlmikroanalysator werden grun leuchtende GaP:N-Dioden (LED's) bei Raumtemperatur untersucht. Linienscans der integralen Katodolumineszenz werden uber dem pn-Ubergang durchgefuhrt. Die Katodolumineszenzprofile werden in Verbindung mit der Tiefe der pn-Ubergange und mit der auseren Quantenausbeute der Dioden diskutiert. In einigen Fallen wird eine Ansammlung von nichtstrahlenden Rekombinationszentren im n-Gebiet nahe dem pn-Ubergang nachgewiesen. Aus dem Vergleich der Katodolumineszenz mit der Elektrolumineszenz wird das Injektionsverhaltnis unter Flusspannung bestimmt.

Details

ISSN :
1521396X and 00318965
Volume :
63
Database :
OpenAIRE
Journal :
Physica Status Solidi (a)
Accession number :
edsair.doi...........0eb25aa3412a629705cfc876fb2bf7df
Full Text :
https://doi.org/10.1002/pssa.2210630215