Back to Search Start Over

Solid phase extraction and preconcentration of cobalt in mineral waters with PAR-loaded Amberlite XAD-7 and flame atomic absorption spectrometry

Authors :
Gokce Kaya
Mehmet Yaman
Muharrem Ince
Source :
Environmental Chemistry Letters. 8:283-288
Publication Year :
2009
Publisher :
Springer Science and Business Media LLC, 2009.

Abstract

A simple, sensitive, accurate, and selective method for determination of ultratrace levels of Co is modified. The method is based on preconcentration of Co on the PAR-loaded Amberlite XAD-7 at pH 2.0 ± 0.2 for contact time as low as 45 min. The adsorbed cobalt was eluted with concentrated nitric acid and measured by flame atomic absorption spectrometry. Recoveries up to 90% were achieved. The optimized preconcentration method was applied to cobalt determination in natural mineral waters. The detection limit was found to be 0.1 ng mL−1. The relative standard deviation was found to be 13% for 600 mL of 2.0 ng mL−1, for 10 replicate preconcentration procedures. Cobalt concentrations in the studied water samples were found to be in the ranges of 0.5–3.5 ng mL−1.

Details

ISSN :
16103661 and 16103653
Volume :
8
Database :
OpenAIRE
Journal :
Environmental Chemistry Letters
Accession number :
edsair.doi...........11b167803395e17d3903ed487dde17b2
Full Text :
https://doi.org/10.1007/s10311-009-0218-x