Back to Search
Start Over
SIMULTANEOUS ESTIMATION OF TRAMADOL HYDROCHLORIDE, PARACETAMOL AND DOMPERIDONE BY RP-HPLC IN TABLET FORMULATION
- Source :
- Journal of Liquid Chromatography & Related Technologies. 33:786-792
- Publication Year :
- 2010
- Publisher :
- Informa UK Limited, 2010.
-
Abstract
- A new high performance liquid chromatography method was developed and validated for the quantitation of tramadol, paracetamol, and domperidone in pharmaceutical formulations. Determination was performed using a Inertsil-ODS-3 (C-18) column (5 μm, 250 mm × 4.60 mm), a mobile phase containing methanol–phosphate buffer (pH 4.0; 40 + 60, v/v), in gradient flow rate 1.2 mL. The method was validated with respect to linearity, precision, robustness, and accuracy. The calibration graphs ranged from 250 to 1500 mg/mL for paracetamol, 25 to 150 mg/mL for tramadol, and 5 to 30 mg/mL for domperidone. Intra- and interday relative standard deviation values for the standard solutions were 0.077%, 0.98%, and 1.04%, respectively. Repeatability of relative standard deviation values was 0.115%, 0.494%, and 1.97% respectively. Total recoveries of paracetamol, tramadol, and domperidone from the laboratory prepared mixtures were 100.4, 100.06, and 100.2%, respectively.
Details
- ISSN :
- 1520572X and 10826076
- Volume :
- 33
- Database :
- OpenAIRE
- Journal :
- Journal of Liquid Chromatography & Related Technologies
- Accession number :
- edsair.doi...........12ff77f5699daedda226bb37c5d7eb84
- Full Text :
- https://doi.org/10.1080/10826071003684224