Back to Search
Start Over
Changes in flow velocity patterns of the superior and inferior venae cavae during placental circulatory insufficiency
- Source :
- Ultrasound in Obstetrics and Gynecology. 21:53-56
- Publication Year :
- 2002
- Publisher :
- Wiley, 2002.
-
Abstract
- Objectives Placental circulatory insufficiency, expressed by the disappearance of the diastolic component of the umbilical artery Doppler velocity waveforms, causes blood flow redistribution that could disturb, to different extents, the systemic venous returns to the heart. The purpose of this study was to investigate the effect of an absence of diastolic blood flow in the umbilical artery on the relationship between the Doppler flow velocities of the venae cavae. Methods Fifteen normal fetuses (normal group) were matched for gestational age with 11 fetuses with absent diastolic flow in the umbilical artery (abnormal group). In the venae cavae, the following Doppler variables were measured and compared between groups: (a) during ventricular systole: maximum (Smax) and minimum velocities (Smin) and velocity integrals (SI); (b) during ventricular diastole: peak velocity of the E-wave and its integral (EI), the A-wave and its integral (AI). A venous velocity index (VVI) was defined as (Smax + Smin)/Smax. Results In the normal group, Smin and VVI were significantly higher in the inferior vena cava (IVC) than in the superior vena cava (SVC). The ratio SVC-VVI/IVCVVI was therefore always less than one. In the abnormal group, Smin, SI, E, EI and VVI were higher in the SVC compared to those of the IVC. The ratio SVC-VVI/IVCVVI was always greater than one. Conclusion In the absence of umbilical artery diastolic flow, a reciprocal shift is observed between the IVC and SVC velocity waveforms characterized by a flow profile in the IVC which resembles that of a normal SVC profile and vice versa. These changes are another manifestationof bloodflowredistributiontowardsthebraininthepresence of placental circulatory insufficiency. They should be taken into account on Doppler assessment of ventricular diastolic function based on venous flow patterns during placental circulatory impairment. Copyright 2002 ISUOG. Published by John Wiley & Sons, Ltd.
- Subjects :
- Radiological and Ultrasound Technology
business.industry
Diastole
Obstetrics and Gynecology
Hemodynamics
Umbilical artery
General Medicine
Placental insufficiency
Anatomy
medicine.disease
Inferior vena cava
Reproductive Medicine
medicine.vein
medicine.artery
Circulatory system
cardiovascular system
medicine
Radiology, Nuclear Medicine and imaging
cardiovascular diseases
Venae cavae
business
Lower limbs venous ultrasonography
Subjects
Details
- ISSN :
- 09607692
- Volume :
- 21
- Database :
- OpenAIRE
- Journal :
- Ultrasound in Obstetrics and Gynecology
- Accession number :
- edsair.doi...........1a72ffbc1561a5d3ac69ce8491c9dd06