Procedural efficacy and safety of standardized, Ablation Index guided fixed 50W high power short duration pulmonary vein isolation and substrate modification using the CLOSE protocol

Authors :
Steffen Schoen
Marian Christoph
Alexander Francke
Nadja S Taha
Frank Scharfe
Carsten Wunderlich
Publication Year :
2021
Publisher :
Authorea, Inc., 2021.

Abstract

Introduction: Ablation Index guided ablation according to the CLOSE protocol is very effective in terms of chronic pulmonary vein isolation (PVI). However, the optimal RF power remains controversial. Here, we thought to investigate the efficiency and safety of an AI guided fixed circumferential 50W high power short duration (HPSD) PVI using the CLOSE protocol Methods and results: In a single-centre prospective “proof of concept” trial 40 patients underwent randomized PVI using AI guided RF ablation without oesophageal temperature monitoring. In 20 patient fixed 50W HPSD was used irrespective to the anatomical localization. 20 subjects were ablated with standard power settings (20W posterior and 40W roof and anterior wall). Additionally, 80 consecutive patients were treated according to the HPSD protocol to gather additional safety data. All patients underwent post-procedural oesophago-gastro-duodenoscopy to reveal oesophageal lesions (EDEL). The mean total procedural time was 80.3±22.5 minutes in HPSD compared to control 109.1±27.4 (p