Back to Search
Start Over
Trigger-timing signal distribution system for the KEK electron/positron injector linac
- Source :
- Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment. 521:549-555
- Publication Year :
- 2004
- Publisher :
- Elsevier BV, 2004.
-
Abstract
- The KEK electron/positron injector linac provides a short-pulse electron beam with an energy of 2.5 GeV for the Photon Factory (PF) storage ring, that with an energy of 3 GeV for the Advanced Ring (PF–AR) for pulse X-rays, and single-bunch electron and positron beams with energies of 8 and 3.5 GeV respectively for the KEK B-Factory (KEKB) storage rings. A trigger-timing signal distribution system of the injector linac was newly developed and extended for stable injection to the KEKB rings with the required injection-timing accuracy highly stabilized to less than 30 ps in root mean square because the old trigger system distributed the trigger-timing signals for the injection to the PF ring and the PF–AR with an injection-timing accuracy of 300 ps . In this report the design and its performance of the new trigger-timing signal distribution system are described in detail.
Details
- ISSN :
- 01689002
- Volume :
- 521
- Database :
- OpenAIRE
- Journal :
- Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Accession number :
- edsair.doi...........1ebb4d4fc77e76fabf9ef473dd8f59f6
- Full Text :
- https://doi.org/10.1016/j.nima.2003.10.101