Status of the BNL LEReC Machine Protection System
- Publication Year :
- 2019
- Publisher :
- JACoW Publishing, Geneva, Switzerland, 2019.
-
Abstract
- The low energy RHIC Electron Cooler (LEReC) will be operating with 1.6-2.6 MeV electron beams having up to 140 kW power. It was determined that under the worst case scenario the missteered electron beam can damage the vacuum chamber and in-vacuum components within 40 us. Hence, the LEReC requires a dedicated fast machine protection system (MPS). The LEReC MPS has been designed and built and currently is under commissioning. In this paper we describe the most recent developments with the LEReC MPS.<br />Proceedings of the 7\textsuperscript{th} Int. Beam Instrumentation Conf., IBIC2018, Shanghai, China
- Subjects :
- 3. Beam loss monitors and machine protection
Accelerator Physics
Subjects
Details
- Language :
- English
- Database :
- OpenAIRE
- Accession number :
- edsair.doi...........20db50312df54338b04b8f5f63444523
- Full Text :
- https://doi.org/10.18429/jacow-ibic2018-tupa17