Back to Search Start Over

Measurements of HO2 uptake coefficient on aqueous (NH4)2SO4 aerosol using aerosol flow tube with LIF system

Authors :
Mingjin Tang
Keding Lu
Huan Song
Qi Zou
Source :
Chinese Chemical Letters. 30:2236-2240
Publication Year :
2019
Publisher :
Elsevier BV, 2019.

Abstract

Laboratory studies of HO2 uptake coefficients, γ(HO2), were conducted at room temperature using an aerosol flow tube coupled with a laser induced fluorescence (LIF) system. The measurement was conducted with atmospherically relevant HO2 concentrations (∼1 × 109 molecule/cm3) at 51% RH. The measured γ(HO2) onto aqueous (NH4)2SO4 aerosol was 0.001 ± 0.0007, which was consistent with the relatively low first-order loss rate of HO2 onto aqueous (NH4)2SO4 aerosol. The γ(HO2) was elevated with increase of Cu(II) concentrations in aqueous (NH4)2SO4 aerosol. The threshold of Cu(II) concentration was 10−3 mol/L for the dramatic increase of γ(HO2). It was found that γ(HO2) reached 0.1 when Cu(II) concentration in aerosol was larger than 10−3 mol/L, suggesting that γ(HO2) is very sensitive to concentration of transition metal ions in aerosol.

Details

ISSN :
10018417
Volume :
30
Database :
OpenAIRE
Journal :
Chinese Chemical Letters
Accession number :
edsair.doi...........242d7f2fa8452913b30b07cf66ac1e3a
Full Text :