Back to Search Start Over

Segmented detector for recoil neutrons in the p(γ, n)π+ reaction

Authors :
G. A. Retzlaff
D. M. Skopik
F.M. Rozon
E. Cairns
D. Jordan
G. V. O'Rielly
D. A. Hutcheon
J. Soukup
E. Korkmaz
N. R. Kolb
A. K. Opper
L. Holm
J. M. Vogt
B.D. Sawatzky
U. Giesen
G. Feldman
R. E. Pywell
Source :
Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment. 431:446-454
Publication Year :
1999
Publisher :
Elsevier BV, 1999.

Abstract

A segmented neutron detector has been constructed and used for recoil neutron (6–13 MeV) measurements of the reaction γp→nπ+ very close to threshold. BC-505 liquid scintillator was used to allow pulse shape discrimination between neutrons and photons. A measurement of the absolute efficiency of the detector was performed using stopped pions in the reaction π−p→nγ. Results of the efficiency calibration are compared to a Monte Carlo simulation.

Details

ISSN :
01689002
Volume :
431
Database :
OpenAIRE
Journal :
Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
Accession number :
edsair.doi...........2a3266bf025639368d7b0431de6044f3
Full Text :
https://doi.org/10.1016/s0168-9002(99)00377-0