Campbell Mode is a method widely used in nuclear signal processing. In this article, we introduce the design of the new system based on the Campbell integration measurement applied in NFM (neutron flux measurement) systems for ITER plasma diagnose. In this article, we introduce a digital particle flux measurement system based on Campbell integration theory. A subsequent series of experiment are conducted to test the digital Campbell system performance, which proves that the Campbell integration system is competent for the plasma diagnose in ITER.