- A radiation shielding study against primary and secondary gas bremsstrahlung is carried out for a tungsten collimator/stop, which is one of the components employed in the VESPERS beamline at the Canadian Light Source. The dose and dose rate are obtained by calculating the energy deposition in a water phantom which surrounds the collimator/stop unit. The dose rate behind a vacuum hole of the collimator/stop which leads to the experimental hutch is closely examined. The dose rates are further investigated with the addition of a tungsten shutter that is positioned in front of the collimator/stop.