Back to Search
Start Over
Space-resolved density diagnostic of a highly ionized holmium (Z=67) laser-produced plasma from 3d104l-3d104l’ Cu i–like lines
- Source :
- Physical Review E. 49:5652-5655
- Publication Year :
- 1994
- Publisher :
- American Physical Society (APS), 1994.
-
Abstract
- A space-resolved electron density diagnostic of a holmium laser-produced plasma has been performed using the intensity ratios of Cu I--like 3[ital d][sup 10]4[ital l]-3[ital d][sup 10]4[ital l][prime] lines. The atomic theoretical model of the Cu I--like ion included the 3[ital d][sup 10][ital nl] levels with [ital n]=4,5 and [ital l]=[ital s],[ital p],[ital d],[ital f]. The effect of line absorption at high electron densities is discussed and the atomic data obtained with the HULLAC computer code are compared with previously published data.
Details
- ISSN :
- 10953787 and 1063651X
- Volume :
- 49
- Database :
- OpenAIRE
- Journal :
- Physical Review E
- Accession number :
- edsair.doi...........3aa8e4c3520fb36f229af443e423c933
- Full Text :