Back to Search Start Over

Diagnostic accuracy of rapid antigen tests in pre-/asymptomatic close contacts of individuals with a confirmed SARS-CoV-2 infection

Authors :
Karel G.M. Moons
Irene Veldhuijzen
Kim Benschop
Susan Pas
Gregorius J. Sips
Lieke Brouwer
Roderick P Venekamp
Corine H. GeurtsvanKessel
Richard Molenkamp
Esther Lodder
Robin C. Huisman
Ewoud Schuit
Janneke van de Wijgert
Wouter van den Bijllaardt
Timo Boelsums
Lotty Hooft
Jans Velzing
Susan van den Hof
Publication Year :
2021
Publisher :
Cold Spring Harbor Laboratory, 2021.

Abstract

BackgroundPre-/asymptomatic close contacts of SARS-CoV-2 infected individuals were tested at day 5 after contact by real-time reverse transcriptase polymerase chain reaction (RT-PCR). Diagnostic accuracy of antigen-detecting rapid diagnostic tests (Ag-RDT) in pre-/asymptomatic close contacts was up till now unknown.MethodsWe performed a prospective cross-sectional diagnostic test accuracy study. Close contacts (e.g. selected via the test-and-trace program or contact tracing app) aged ≥16 years and asymptomatic when requesting a test, were included consecutively and tested at day 5 at four Dutch public health service test sites. We evaluated two Ag-RDTs (BD Veritor™ System Ag-RDT (BD), and Roche/SD Biosensor Ag-RDT (SD-B)) with RT-PCR as the reference standard. Virus culture was performed in RT-PCR positive individuals to determine the viral load cut-off above which 95% was culture positive, as a proxy of infectiousness.ResultsOf 2,678 BD-tested individuals, 233 (8.7%) were RT-PCR positive and BD detected 149 (sensitivity 63.9%; 95% confidence interval 57.4%-70.1%). Out of 1,596 SD-B-tested individuals, 132 (8.3%) were RT-PCR positive and SD-B detected 83 (sensitivity 62.9%; 54.0%-71.1%). When applying an infectiousness viral load cut-off ≥ 5.2 log10 gene copies/mL, the sensitivity was 90.1% (84.2%-94.4%) for BD, 86.8% (78.1% to 93.0%) for SD-B overall, and 88.1% (80.5%-93.5%) for BD, 85.1% (74.3%-92.6%) for SD-B for those still asymptomatic at the actual time of sampling. Specificity was >99% for both Ag-RDTs in all analyses.ConclusionsThe sensitivity for detecting SARS-CoV-2 of both Ag-RDTs in pre-/asymptomatic close contacts is over 60%, increasing to over 85% after applying an infectiousness viral load cut-off.Trial registration numberNot applicable. A study protocol is available upon request.

Details

Database :
OpenAIRE
Accession number :
edsair.doi...........3b6cfaf5b4d805ce68ffb9cb0458c9c2
Full Text :
https://doi.org/10.1101/2021.03.18.21253874