Back to Search
Start Over
Minimal Invasive Left Ventricular Lead Repositioning is Safe and Effective in Distal Left Ventricular Lead Positions
- Source :
- Pacing and Clinical Electrophysiology. 40:488-493
- Publication Year :
- 2017
- Publisher :
- Wiley, 2017.
-
Abstract
- Background Treatment of left ventricular electrode dislocation and phrenic nerve stimulation remains an issue in the era of new electrode designs. Methods Safety and efficacy of minimal invasive lead repositioning and pocket opening reposition procedures were evaluated between December 2005 and December 2012 at our center. Minimal invasive method was developed and widely utilized at our center to treat phrenic nerve stimulation. The distally positioned left ventricular lead is looped around by a deflectable catheter in the right atrium introduced from the femoral vein access and then pulled back. Coronary stent implantation was used afterwards for lead stabilization in some patients. Results 42 minimal invasive and 48 electrode repositions with pacemaker pocket opening were performed at 77 patients for left ventricular lead problems. Minimal invasive reposition could be carried out successfully in 69% of (29 patients) cases. Note that in 14.3% of the cases (six patients) minimal invasive procedures were acutely unsuccessful and crossover was necessary. In 16.6% of the cases (seven patients) lead issues were noted later during follow-up. Opening of the pocket could be carried out successfully in 81.2% (39 patients) and was unsuccessful acutely in 6.25% (three patients). Repeated dislocation was noticed, 12.5%, in this group (six patients). Complication during minimal invasive procedures was electrode injury in one case. Pocket openings were associated with several complications: atrial fibrillation, pericardial effusion, fever, hematoma, and right ventricular electrode dislodgement. Conclusion Minimal invasive procedure-as the first line approach-is safe and feasible for left ventricular electrode repositioning in selected cases.
- Subjects :
- medicine.medical_specialty
business.industry
medicine.medical_treatment
Femoral vein
Atrial fibrillation
General Medicine
030204 cardiovascular system & hematology
medicine.disease
Pericardial effusion
Surgery
03 medical and health sciences
Catheter
0302 clinical medicine
Hematoma
Coronary stent
medicine
030212 general & internal medicine
Cardiology and Cardiovascular Medicine
Complication
Lead (electronics)
business
Subjects
Details
- ISSN :
- 01478389
- Volume :
- 40
- Database :
- OpenAIRE
- Journal :
- Pacing and Clinical Electrophysiology
- Accession number :
- edsair.doi...........3c64e0b220bf17fbc4ce63cef85b1397
- Full Text :
- https://doi.org/10.1111/pace.13068