Back to Search Start Over

Operational Results of Simultaneous Four-Beam Delivery at Jefferson Lab

Authors :
Kazimi, Reza
Freyberger, Arne
Grames, Joseph
Hansknecht, John
Hofler, Alicia
Plawski, Tomasz
Poelker, Matt
Spata, Michael
Wang, Yan
Publication Year :
2019
Publisher :
JACoW Publishing, Geneva, Switzerland, 2019.

Abstract

A concept for simultaneous beam delivery to all four CEBAF experimental halls from a single injector and a single main accelerator for the 12 GeV era was proposed in 2012. The original 12 GeV beam delivery plan was for a maximum of three experimental halls at a time as in the 6 GeV era. Therefore, the new concept increases the po-tential beam time for the experiments up to 33%. This change, although a major improvement in operational capabilities, required only limited modifications to the existing machine. The modifications were mainly timing and pattern changes to the beams in the injector, adding a fourth laser to the photo-cathode gun, and the addition of new RF separators to the highest pass of CEBAF. These changes are now complete and, for the first time, the full system is operating, producing four simultaneous beams through the accelerator to four different destinations. In this paper, in addition to presenting the results of the full system commissioning, we will discuss important details about the new configuration plus some of our operational challenges.<br />Proceedings of the 10th Int. Particle Accelerator Conf., IPAC2019, Melbourne, Australia

Details

Language :
English
Database :
OpenAIRE
Accession number :
edsair.doi...........3f8d0555f7f6e99f4518f82a3753a80b
Full Text :
https://doi.org/10.18429/jacow-ipac2019-wepmp053