Tissue response to applied loading using different designs of penile compression clamps

Authors :
Joseph Mh Lemmens
Katherine N. Moore
Marcus J. Drake
Rowland W. Rees
Margaret Macaulay
Mandy Fader
Jackie Broadbridge
Matt Archer
Dan L. Bader
Source :
Medical Devices: Evidence and Research. 12:235-243
Publication Year :
2019
Publisher :
Informa UK Limited, 2019.

Abstract

Background: Penile compression devices (PCD) or clamps are applied to compress the urethra and prevent urinary incontinence (UI). PCDs are more secure and less likely to leak than pads, allowing men the opportunity to participate in short-term, vigorous activities. However, they are uncomfortable, can cause pressure ulcers (PU) and affect penile blood flow. No objective assessment of tissue health has been undertaken to assess and compare different PCD designs and to provide guidance on safe use. Objective: This study was designed to evaluate existing PCDs in terms of their physiological response and potential for pressure-induced injury. Design, setting and participants: Six men with post-prostatectomy UI tested four selected PCDs at effective pressures, in a random order, in a controlled laboratory setting. Outcome measurements and statistical analysis: Using objective methods for assessing skin injury, PCDs were measured in situ for their effects on circulatory impedance, interface pressures and inflammatory response. Results and limitations: There was evidence for PCD-induced circulatory impedance in most test conditions. Interface pressures varied considerably between both PCDs and participants, with a mean value of 137.4±69.7 mmHg. In some cases, penile skin was noted to be sensitive to loading with elevated concentration of the cytokine IL-1α after 10 mins wear, indicating an inflammatory response. IL-1α levels were restored to baseline 40 mins following PCD removal. Conclusion: Skin health measures indicated tissue and blood flow compromise during the 50 mins of testing using all PCDs. Although there was an elevation in pro-inflammatory cytokines, PCDs did not cause sustained irritation and skin health measures recovered 40 mins after PCD removal. This research indicates that application of a clamp for one hour with an equal clamp free time before reapplication is likely to be safe. Longer periods are often recommended by manufacturers but have yet to be tested.

Details

ISSN :
11791470
Volume :
12
Database :
OpenAIRE
Journal :
Medical Devices: Evidence and Research
Accession number :
edsair.doi...........4165c5fa89adaa3754de90e6d7fda3a2
Full Text :
https://doi.org/10.2147/mder.s188888