Back to Search Start Over

Creation of a functional tricuspid valve: Novel use of percutaneously implanted valve in right atrial to right ventricular conduit in a patient with tricuspid atresia

Creation of a functional tricuspid valve: Novel use of percutaneously implanted valve in right atrial to right ventricular conduit in a patient with tricuspid atresia

Authors :
Syed Najaf Nadeem
Xenos Mason
Lee N. Benson
Eric Horlick
David Tanous
Jack M. Colman
Source :
International Journal of Cardiology. 144:e8-e10
Publication Year :
2010
Publisher :
Elsevier BV, 2010.

Abstract

We report the first use of a stented pulmonic valve within the right atrial to right ventricular conduit of a patient who underwent a Bjork modification Fontan for tricuspid atresia. In effect, a functional tricuspid valve was created. This case report demonstrates the feasibility of transcatheter valve replacement in positions other than the pulmonic or aortic valve and that future revision of conduits in the Bjork modification Fontan can be performed percutaneously.