Rates of Upgrade of ICD Recipients to CRT in Clinical Practice and the Potential Impact of the More Liberal Use of CRT at Initial Implant
- Source :
- Pacing and Clinical Electrophysiology. 35:73-80
- Publication Year :
- 2011
- Publisher :
- Wiley, 2011.
-
Abstract
- Background: Many implantable cardioverter defibrillator (ICD) recipients may develop indications for cardiac resynchronization therapy (CRT) during follow-up. However, the actual upgrade rate during follow-up in clinical practice is not known. Methods: We performed a single center retrospective observational study of all new ICD implants over 5 years (2003–2007). The rate of CRT upgrade of patients initially implanted with a single-/dual-chamber ICD during follow-up was assessed. The impact of using alternative criteria on the need for CRT in ICD recipients at initial implant was also evaluated. Results: During the study period, there were 549 new ICD implants. The initial implant was a single/dual-chamber ICD in 73% (n = 399) and a CRT-D in 27% (n = 150). During follow-up (48±20 months) of the 399 ICD recipients, 70 (17.5%) died and 15 (3.8%) were upgraded to CRT, including eight cases where left ventricular lead implant had been initially unsuccessful. Upgrade rates at 1, 3, and 5 years were 0.03%, 2.4%, and 5.1%, respectively. Using alternative CRT criteria (left ventricular ejection fraction [LVEF]≤30%, QRS ≥130 ms, New York Heart Association I-IV) 42.6% (n = 234) of ICD recipients met criteria for CRT at initial implant. Conclusion: In this retrospective single center study, rates of CRT upgrade in ICD recipients over the medium term were low, which may reflect underuse in otherwise appropriate candidates. The more liberal use of CRT at initial implant in patients with a reduced LVEF, a broad QRS, but only mild heart failure symptoms would require approximately 50% increase in CRT use in ICD recipients at initial implant, and may help address some of the suggested underutilization. (PACE 2012; 35:73–80)
- Subjects :
- medicine.medical_specialty
Ejection fraction
business.industry
medicine.medical_treatment
Cardiac resynchronization therapy
Retrospective cohort study
General Medicine
Implantable cardioverter-defibrillator
Single Center
medicine.disease
QRS complex
Internal medicine
Heart failure
cardiovascular system
medicine
Cardiology
cardiovascular diseases
Implant
Cardiology and Cardiovascular Medicine
business
circulatory and respiratory physiology
Subjects
Details
- ISSN :
- 01478389
- Volume :
- 35
- Database :
- OpenAIRE
- Journal :
- Pacing and Clinical Electrophysiology
- Accession number :
- edsair.doi...........48b27dec2deadf348aba42a02a44b59d
- Full Text :
- https://doi.org/10.1111/j.1540-8159.2011.03255.x