Back to Search Start Over

Sex Differences in Adenosine-Free Coronary Pressure Indexes

Authors :
Giovanni Esposito
Bernard De Bruyne
Colin Berry
Emanuele Barbato
Nils P. Johnson
Bon-Kwon Koo
Allen Jeremias
Nils Witt
Sonia Shah
William F. Fearon
Seung-Jung Park
Frederik M. Zimmermann
Takeshi Nishi
Contrast Study Investigators
Yuhei Kobayashi
Nico H.J. Pijls
Gilles Rioufol
Keith G. Oldroyd
Source :
JACC: Cardiovascular Interventions. 11:1454-1463
Publication Year :
2018
Publisher :
Elsevier BV, 2018.

Abstract

Objectives The goal of this study was to investigate sex differences in adenosine-free coronary pressure indexes. Background Several adenosine-free coronary pressure wire indexes have been proposed to assess the functional significance of coronary artery lesions; however, there is a theoretical concern that sex differences may affect diagnostic performance because of differences in resting flow and distal myocardial mass. Methods In this CONTRAST (Can Contrast Injection Better Approximate FFR Compared to Pure Resting Physiology?) substudy, contrast fractional flow reserve (cFFR), obtained during contrast-induced submaximal hyperemia, the instantaneous wave-free ratio (iFR), and distal/proximal coronary pressure ratio (Pd/Pa) were compared with fractional flow reserve (FFR) in 547 men and 216 women. Using FFR ≤0.8 as a reference, the diagnostic performance of each index was compared. Results Men and women had similar diameter stenosis (p = 0.78), but women were less likely to have FFR ≤0.80 than men (42.5% vs. 51.5%, p = 0.04). Sensitivity was similar among cFFR, iFR, and Pd/Pa when comparing women and men, respectively (cFFR, 77.5% vs. 75.3%; p = 0.69; iFR, 84.9% vs. 79.4%; p = 0.30; Pd/Pa, 78.8% vs. 77.3%; p = 0.78). cFFR was more specific than iFR or Pd/Pa regardless of sex (cFFR, 94.3% vs. 95.8%; p = 0.56; iFR, 75.6% vs. 80.1%; p = 0.38; Pd/Pa, 80.6% vs. 78.7%; p = 0.69). By receiver-operating characteristic curve analysis, cFFR provided better diagnostic accuracy than resting indexes irrespective of sex (p ≤ 0.0001). Conclusions Despite the theoretical concern, the diagnostic sensitivity and specificity of cFFR, iFR, and Pd/Pa did not differ between the sexes. Irrespective of sex, cFFR provides the best diagnostic performance.

Details

ISSN :
19368798
Volume :
11
Database :
OpenAIRE
Journal :
JACC: Cardiovascular Interventions
Accession number :
edsair.doi...........4b0c39ef3ac00094142608eade858ba8
Full Text :
https://doi.org/10.1016/j.jcin.2018.03.030