Back to Search
Start Over
In situ study of the resistance of the electropolymerized polypyrrole film using platinum dual-disk microelectrodes
- Source :
- Journal of Electroanalytical Chemistry. 441:51-55
- Publication Year :
- 1998
- Publisher :
- Elsevier BV, 1998.
-
Abstract
- The resistance of the polypyrrole film (PPy) was measured in situ by the dual-disk microelectrode. Some factors (such as the kinds of electrolyte, anionic concentration, oxidation potential and solution pH) which influence the resistance or the stability of the film have been studied in detail. The oxidation potential had the most critical effect on the resistance and the stability of the film.
Details
- ISSN :
- 15726657
- Volume :
- 441
- Database :
- OpenAIRE
- Journal :
- Journal of Electroanalytical Chemistry
- Accession number :
- edsair.doi...........4b9cb1ab66a2a66772d036fa163c2611
- Full Text :
- https://doi.org/10.1016/s0022-0728(97)00336-7