Experimental Investigation on the Interruption Performance of Vacuum Interrupters With AMF and TMF Contacts in a Quench Protection Switch

Authors :
Zongqian Shi
Shenli Jia
Yuhan Liu
Linyan Zhao
Lijun Wang
Sheng Li
Dongdong Ding
Source :
IEEE Transactions on Plasma Science. 47:3549-3553
Publication Year :
2019
Publisher :
Institute of Electrical and Electronics Engineers (IEEE), 2019.

Abstract

A quench protection switch (QPS) is indispensable to protect the magnet coils from the damage of quench in a superconducting Tokamak. In this paper, a QPS based on artificial current zero is involved. The vacuum circuit breaker (VCB), which is driven by a high-speed electromagnetic repulsion mechanism, is used as the main circuit breaker (MCB). Two kinds of commercial vacuum interrupters (VIs), which have contacts generating axial magnetic field (AMF) and transverse magnetic field (TMF), respectively, are applied. The breaking current with an amplitude of 10~25 kA is generated by an LC oscillating circuit. The countercurrent with frequency in the range of 500–3000 Hz is provided by a commutation branch. The interruption performance of the two kinds of VIs under different breaking current and countercurrent frequencies is investigated. The experimental results indicate that the differences in interruption performance under the two types of contacts are increasing with larger frequencies of countercurrents.