Analysis of steady-state and transient modes in the 110/35 kV district electric power system
- Publication Year :
- 2021
- Publisher :
- СанкÑ-ÐеÑеÑбÑÑгÑкий полиÑÐµÑ Ð½Ð¸ÑеÑкий ÑнивеÑÑиÑÐµÑ ÐеÑÑа Ðеликого, 2021.
-
Abstract
- Тема вÑпÑÑкной квалиÑикаÑионной ÑабоÑÑ: «Ðнализ ÑÑÑановивÑÐ¸Ñ ÑÑ Ð¸ пеÑÐµÑ Ð¾Ð´Ð½ÑÑ Ñежимов в Ñайонной ÑлекÑÑоÑнеÑгеÑиÑеÑкой ÑиÑÑеме 110/35 кл. РпÑоÑеÑÑе ÑабоÑÑ Ð¸ÑÑледÑеÑÑÑ ÑлекÑÑоÑнеÑгеÑиÑеÑÐºÐ°Ñ ÑиÑÑема 110/35 кÐ, в Ñ Ð¾Ð´Ðµ коÑоÑого Ð½ÐµÐ¾Ð±Ñ Ð¾Ð´Ð¸Ð¼Ð¾ бÑло вÑбÑаÑÑ Ð¾Ð±Ð¾ÑÑдование â ÑиловÑе ÑÑанÑÑоÑмаÑоÑÑ Ð¸ пÑовода ÑеÑÐµÐ½Ð¸Ñ Ð»Ð¸Ð½Ð¸Ð¹ ÑлекÑÑопеÑедаÑи Ñаким обÑазом, ÑÑÐ¾Ð±Ñ Ð¾Ð½Ð¸ могли вÑдеÑживаÑÑ Ð½Ð°Ð³ÑÑзки в ноÑмалÑном и аваÑийном ÑÐµÐ¶Ð¸Ð¼Ð°Ñ . Ðомимо вÑбоÑа обоÑÑÐ´Ð¾Ð²Ð°Ð½Ð¸Ñ Ð±Ñл пÑоизведен ÑÑÑной ÑаÑÑÐµÑ ÑÑÑановивÑегоÑÑ Ñежима ÑиÑÑемÑ, а Ñакже иÑполÑзÑÑ Ð¿ÑогÑÐ°Ð¼Ð¼Ñ Rastr. РпÑогÑамме Rastr Ð½ÐµÐ¾Ð±Ñ Ð¾Ð´Ð¸Ð¼Ð¾ бÑло поÑÑиÑаÑÑ Ð¼Ð°ÐºÑималÑнÑй и минималÑнÑй Ñежим. ÐажнÑм Ñазделом ÑвлÑеÑÑÑ ÑаÑÑÐµÑ Ñоков неÑиммеÑÑиÑного ÐÐ, где Ð½ÐµÐ¾Ð±Ñ Ð¾Ð´Ð¸Ð¼Ð¾ бÑло ÑаÑÑÑиÑаÑÑ Ñоки и напÑÑÐ¶ÐµÐ½Ð¸Ñ Ð¿Ñи двÑÑ Ñазном ÐРна Ð·ÐµÐ¼Ð»Ñ Ð² конÑе воздÑÑной линии 2. Также бÑли поÑÑÑÐ¾ÐµÐ½Ñ Ð²ÐµÐºÑоÑнÑе диагÑÐ°Ð¼Ð¼Ñ Ñоков и напÑÑжений Ð´Ð»Ñ Ð´Ð°Ð½Ð½Ð¾Ð³Ð¾ вида ÐÐ. Ðомимо ÑÑого, в пÑогÑамме EMTP ÑаÑÑÑиÑан Ñок Ð´Ð»Ñ Ð´Ð²ÑÑ Ñазного ÐÐ. ÐÑÑледование ÑиÑÑÐµÐ¼Ñ Ð½Ð° динамиÑеÑкÑÑ ÑÑÑойÑивоÑÑÑ Ð²Ð¾Ð·Ð¼Ð¾Ð¶Ð½Ð¾ пÑи помоÑи пÑогÑÐ°Ð¼Ð¼Ñ Dymola. ÐополниÑелÑнÑм заданием Ð´Ð»Ñ Ð¿Ð¾Ð²ÑÑÐµÐ½Ð¸Ñ Ð´Ð¸Ð½Ð°Ð¼Ð¸ÑеÑкой ÑÑÑойÑивоÑÑи ÑвлÑлоÑÑ Ð¿Ð°ÑаллелÑное ÑлекÑÑиÑеÑкое ÑоÑможение, Ñ Ð¿Ð¾Ð¼Ð¾ÑÑÑ ÐºÐ¾ÑоÑого ÑдалоÑÑ ÑвелиÑиÑÑ Ð¿ÑеделÑное вÑÐµÐ¼Ñ Ð¾ÑклÑÑÐµÐ½Ð¸Ñ Ð»Ð¸Ð½Ð¸Ð¸.<br />The topic of the graduation work: "Analysis of steady-state and transient modes in the district electric power system 110/35 kV". In the process of work, the electric power system of 110/35 kV is being investigated, during which it was necessary to select equipment - power transformers and wires of the cross-section of power lines so that they could withstand loads in normal and emergency modes. In addition to the choice of equipment, a manual calculation of the steady state of the system was made, as well as using the Rastr program. In the Rastr program, it was necessary to calculate the maximum and minimum modes. An important section is the calculation of asymmetric short-circuit currents, where it was necessary to calculate currents and voltages for a two-phase short circuit to the ground at the end of the overhead line 2. Vector diagrams of currents and voltages for this type of short circuit were also built. In addition, the current for a two-phase short circuit was calculated in the EMTP program. Dynamic stability analysis of the system is possible using the Dymola program. An additional task to increase the dynamic stability was parallel electric braking, with the help of which it was possible to increase the limit time for disconnecting the line.
- Subjects :
- динамиÑеÑÐºÐ°Ñ ÑÑÑойÑивоÑÑÑ
two-phase short circuit to ground
ÑÑÐµÑ Ñазное ÐÐÐ
ÑÑÑановивÑийÑÑ Ñежим
dynamic stability
steady state
паÑаллелÑное ÑлекÑÑиÑеÑкое ÑоÑможение
three-phase automatic reclosing
electric power system
ÑлекÑÑоÑнеÑгеÑиÑеÑÐºÐ°Ñ ÑиÑÑема
двÑÑ Ñазное коÑоÑкое замÑкание на землÑ
parallel electric braking
Subjects
Details
- Language :
- Russian
- Database :
- OpenAIRE
- Accession number :
- edsair.doi...........4e40b5c82a83cd59fb57b46db29c0332
- Full Text :
- https://doi.org/10.18720/spbpu/3/2021/vr/vr21-3470