Back to Search
Start Over
Study on stability test of in process sample of recombinant Protein A
- Source :
- Analytical Science and Technology. 25:483-491
- Publication Year :
- 2012
- Publisher :
- The Korean Society of Analytical Science, 2012.
-
Abstract
- This study is to investigate the issues on how to secure stability during the purification process for the production of recombinant protein A. The final recombinant protein A is produced by passing through the cation exchange column (SP) and the anion-exchange column (Q) during the production process, for which the samples produced by the step-by-step processes can be exposed to trouble in securing stable storage in case the next process cannot be taken within the proper time period. Accordingly, this study aims to evaluate the proper storage conditions and length of time when storing samples produced in the production process. That is, in this study, how to store fair samples, how long the storage period should be set up, and how to evaluate the security of its quality depending on time are dealt with. The items to be experimented with were enodotoxin, SDS-PAGE, HPLC purity and concentration. Experimental results showed that after passing the cation exchange column, when stored at 4 ℃C or room temperature, SDS-PAGE showed a major band, endotoxin is 5.0 Eu/mg or less, and concentration is on average of 8.21 to 8.24 mg/mL and RSD% 0.10~0.62%. In addition, HLPC purity showed somewhat stable results; at the HPLC purity 214 nm, the average is 99.24% to 99.37% and RSD% is 0.22~0.29%, while the average is 89.72% to 89.80% and RSD% 0.62~1.26% at 280 nm. On the contrary, after passing the anion exchange column, when stored at 4 oC or room temperature, SDS-PAGE revealed the major band, endotoxin is 0.5 Eu/mg or less, and concentration is on average of 5.59 mg/mL and RSD% 0.03~0.10%. when it comes to HLPC purity, the result showed that at the HPLC purity 214 nm, the average is 99.74% and RSD% is 0.10~0.11%, while the average is 96.16% to 96.85% and RSD% 0.72~1.13%. In conclusion, the stability of fair samples of recombinant protein A during the manufacturing process could be obtained without substance decomposition for 7~8 days at 4 ℃ or 20~21 days at room temperature.
- Subjects :
- Pharmacology
Chromatography
Stability test
Chemistry
Manufacturing process
Sample (material)
Anion exchange column
Decomposition
High-performance liquid chromatography
Analytical Chemistry
Major band
law.invention
law
Materials Chemistry
Recombinant DNA
Environmental Chemistry
Agronomy and Crop Science
Food Science
Subjects
Details
- ISSN :
- 12250163
- Volume :
- 25
- Database :
- OpenAIRE
- Journal :
- Analytical Science and Technology
- Accession number :
- edsair.doi...........52962f15f6ebf992e3ce2286550e186f
- Full Text :
- https://doi.org/10.5806/ast.2012.25.6.483