Back to Search Start Over

The anomalous effects in the three-electrode system for dielectric loss measurements

Authors :
Kwan C. Kao
Song-Zhen Wu
Heng-Kun Xie
Show-Tien Chen
Source :
1983 EIC 6th Electrical/Electronical Insulation Conference.
Publication Year :
1983
Publisher :
IEEE, 1983.

Abstract

The physical parameters of the guard gap between the guard and the guarded electrodes of the three electrode system generally used for dielectric loss measurements can be modelled by a simple T-network. Theoretical analysis shows that under certain conditions these parameters can cause great errors or even make the apparent dissipation factor negative, when measured with a Schering bridge. The sharp edges of the guard and the guarded electrodes may result in the creation of high local fields and give rise to electric discharges under high voltage conditions. Local discharges near the sharp edges directly modify the physical parameters of the guard gap. Such anomalous phenomena have been experimentally observed and they can be attributed to the change in physical parameters in the guard gap. Experimental results are in good agreement with the theoretical analysis based on the T-network model.

Details

Database :
OpenAIRE
Journal :
1983 EIC 6th Electrical/Electronical Insulation Conference
Accession number :
edsair.doi...........52de694abe0e0d62361a27ea49611411
Full Text :
https://doi.org/10.1109/eeic.1983.7465103