Back to Search
Start Over
Effects of structural damping on wind-induced responses of a 243-meter-high solar tower based on a novel elastic test model
- Source :
- Journal of Wind Engineering and Industrial Aerodynamics. 172:1-11
- Publication Year :
- 2018
- Publisher :
- Elsevier BV, 2018.
-
Abstract
- The effects of structural damping to the responses of the vortex-induced vibration of solar tower should be investigated carefully to provide a reference for the structural designers. A new type of elastic test model for a 243-meter-high solar tower is particularly designed and manufactured. A core beam is designed in the test model to simulate the stiffness of the concrete structure, and a coat with baseplate (like a cup) is designed to simulate the steel structure. A structural damping ratio as low as 0.3% is realized, and four level of structural damping ratio, including 0.7%, 1.0%, 1.5% and 2.0%, can be conveniently achieved. A series wind tunnel tests are carried out to investigate the features of the wind-induced responses of the solar tower at the structural damping level of 0.3%, 0.7%, 1.0%, 1.5% and 2.0%. The results show that obvious vortex-induced vibration could be found within wind velocity range of U10 = 21.5–28.4 m/s for the structural damping ratio of 0.7%. At this time, the highest vortex-induced responses (at the wind velocity of U10 = 23.2 m/s), including acceleration at the top, base shear and base moment, are far larger than those at the design wind velocity (U10 = 41.0 m/s). Moreover, it appears that the wind-induced responses in cross-wind direction are far higher than those in the along-wind direction. The most important point is that the base shear and moment in the cross-wind direction measured from wind tunnel tests are far higher than the values obtained from the Code ACI 307–08. The wind-induced responses of the solar tower are extremely sensitive to the structural damping of the test model. For example, the highest acceleration, base shear and moment in cross-wind direction are respectively reduced by about 67%, 74%, 71% when structural damping ratio slightly increases from 0.7% to 1.0%. It seems that the vortex-induced vibration of the solar tower could be effectively mitigated if the structural damping ratio could be enhanced over 1.0%.
- Subjects :
- Physics
Damping ratio
Renewable Energy, Sustainability and the Environment
business.industry
020209 energy
Mechanical Engineering
02 engineering and technology
Structural engineering
01 natural sciences
Wind speed
010305 fluids & plasmas
Vibration
Moment (mathematics)
Shear (sheet metal)
Acceleration
Physics::Space Physics
0103 physical sciences
0202 electrical engineering, electronic engineering, information engineering
business
Beam (structure)
Civil and Structural Engineering
Wind tunnel
Subjects
Details
- ISSN :
- 01676105
- Volume :
- 172
- Database :
- OpenAIRE
- Journal :
- Journal of Wind Engineering and Industrial Aerodynamics
- Accession number :
- edsair.doi...........52f8b0bd476ebd981b1d25ccbaf9ae84
- Full Text :
- https://doi.org/10.1016/j.jweia.2017.10.027