Back to Search Start Over

Wideband TEM-TE11 mode convertor for HPM applications

Authors :
D N Bykov
I K Kurkan
N M Bykov
Source :
Journal of Physics: Conference Series. 830:012037
Publication Year :
2017
Publisher :
IOP Publishing, 2017.

Abstract

The mode convertor design of fundamental coaxial TEM to the lowest asymmetric TE11-mode of a circular waveguide was proposed and optimized with ANSYS HFSS software. It includes axially aligned parts: the input coaxial line with the high voltage insulator, conical coaxial matching line, wave-coax transition section and output circular waveguide. The most losses in this type of convertor caused by the wave of coaxial TE11-mode running back to the microwave source. To minimize these losses, there is the matching conical coaxial line with the cut-off insertion for coaxial TE11-mode. Characteristics of the convertor are as follows: the maximum input peak power – 3GW, the input impedance – 28Ohm, the central operating frequency – 1.14GHz. The power conversion efficiency to the output mode is from 90% upto 100% in the frequency band of 20%.

Details

ISSN :
17426596 and 17426588
Volume :
830
Database :
OpenAIRE
Journal :
Journal of Physics: Conference Series
Accession number :
edsair.doi...........5c44034a8671e096cf81ed8805b1f8b9
Full Text :
https://doi.org/10.1088/1742-6596/830/1/012037