Back to Search
Start Over
Calibration of a single reference receiver VNAs for non-insertable devices test
- Source :
- 2017 IEEE 17th International Conference on Communication Technology (ICCT).
- Publication Year :
- 2017
- Publisher :
- IEEE, 2017.
-
Abstract
- When measuring a non-insertable device using a vector network analyzer, calibration based on eight-term error model such as TRL or SOLR is commonly used. The VNA is in the form of a single reference receiver, and the signals of the two reference receivers cannot be measured simultaneously during calibration. In this paper, we propose a method based on different error models transformation to calculate the switching error terms and realize the eight-term error model calibration of single reference receiver VNAs.
Details
- Database :
- OpenAIRE
- Journal :
- 2017 IEEE 17th International Conference on Communication Technology (ICCT)
- Accession number :
- edsair.doi...........634e5d160c556c794b9d4abdea7926f8