Back to Search
Start Over
Infections in patients using ventricular-assist devices: Comparison of the diagnostic performance of 18F-FDG PET/CT scan and leucocyte-labeled scintigraphy
- Source :
- Journal of Nuclear Cardiology. 26:42-55
- Publication Year :
- 2018
- Publisher :
- Springer Science and Business Media LLC, 2018.
-
Abstract
- The usage of left-ventricular-assist device (LVAD) is increasing in patients presenting with advanced heart failure. However, device-related infections are a challenge to recognize and to treat, with an important morbidity and mortality rate. The role of nuclear medicine imaging remains not well established for LVAD infections. The present study compared the accuracy of positron emission tomography/computed tomography with 18F-fludeoxyglucose (18F-FDG PET/CT) and radiolabeled leucocyte scintigraphy for the diagnosis of infections in patients supported with a continuous-flow LVAD. From a prospectively maintained database, we retrospectively analyzed the diagnostic performance of radiolabeled leucocyte scintigraphy and 18F-FDG PET/CT in 24 patients who had a LVAD with a suspected device-related infection. Both examinations were routinely performed in all patients. Infection was assessed by the International Society for Heart and Lung Transplantation criteria. Twenty-four patients were included: 15 had a specific VAD infection (5 cardiac-LVAD and 10 driveline), 6 had a VAD-related infection, while 3 patients had a non-VAD-related infection. Sensitivity, specificity, positive predictive value, negative predictive value, and accuracy were 95.2%, 66.7%, 95.2%, 66.7%, and 91.6%, respectively, for 18F-FDG-PET; and 71.4%, 100%, 100%, 33.3%, and 75%, respectively, for leucocyte scintigraphy. 18F-FDG PET/CT showed significantly higher sensitivity (P = 0.01) than leucocyte scintigraphy. 18F-FDG PET/CT and radiolabeled leucocyte scintigraphy single-photon emission computed tomography carry high performance in the diagnostic of LVAD infections. 18F-FDG PET/CT shows significantly higher sensitivity and could be proposed as first-line nuclear medicine procedure.
- Subjects :
- medicine.diagnostic_test
business.industry
Mortality rate
medicine.medical_treatment
030204 cardiovascular system & hematology
Scintigraphy
medicine.disease
030218 nuclear medicine & medical imaging
03 medical and health sciences
0302 clinical medicine
Positron emission tomography
Heart failure
medicine
Lung transplantation
Radiology, Nuclear Medicine and imaging
Fdg pet ct
In patient
Cardiology and Cardiovascular Medicine
Nuclear medicine
business
Emission computed tomography
Subjects
Details
- ISSN :
- 15326551 and 10713581
- Volume :
- 26
- Database :
- OpenAIRE
- Journal :
- Journal of Nuclear Cardiology
- Accession number :
- edsair.doi...........67f612fb2846e10822c6d2421f198b0c
- Full Text :
- https://doi.org/10.1007/s12350-018-1323-7