- In this paper, a simple natural convection heat-transfer model for a safety rod placed in a perforated guide tube is proposed. The geometry is typical of the Savannah River K reactor. The proposed model for the rod and the perforated guide-tube assembly is benchmarked against prototypical test data obtained by Idaho National Engineering Laboratory. The results showed that the proposed model was in good agreement with the experimental data except at very high temperatures where the model slightly underpredicted the rod and tube temperatures. By evaluating the thermal conductivity of the fluid (air) at the wall temperature, the prediction of the high temperature natural convection data was further improved.