Back to Search Start Over

The Fault Diagnosis for the Unplanned Downtime of the Roller Disassembly Machine

Authors :
Ying Jun Dai
Guang Zhen Cheng
Yu Jing Jia
Source :
Applied Mechanics and Materials. :469-472
Publication Year :
2012
Publisher :
Trans Tech Publications, Ltd., 2012.

Abstract

This paper provides a kind of fault diagnosis method. It introduces the principles of the electrical control of roller Disassembly machine and the phenomenon of sudden power failure in the work. By analyzing a variety of factors that may lead to fault, and taking some appropriate solution, According to calculations, replaced the control transformer as the BK-300 that keep the roller disassembly machine safe and reliable, and avoid the phenomenon of power failure. Point out That the control transformer capacity should meet the required transformer capacity of the control circuit when it has the maximum load; Some control components have been working, when other control components is started, it still remains active.

Details

ISSN :
16627482
Database :
OpenAIRE
Journal :
Applied Mechanics and Materials
Accession number :
edsair.doi...........72adea86343d5da4554b361a8f0fe12d